TD6 pressure transducers provide a non-amplified current signal (mV)
directly proportional to the value of the pressure input to which they are
connected.
4 wire electrical connections.
Technical Features:
TD6 series: plated carbon steel body.
TD6X series: AISI 316 stainless steel body.
Connection to the system: 1/4" BSP threaded male
Installation position: it can be mounted in any position.
Signal output: min0.2 - max 3.6 mV/V
Zero balance: min 0.1 - max 0.2 mV/V
Working temperature: from -25°C to +125°C
Non linearity + hysteresis: < 0.4% of F.S.
Zero thermic drift: ± 3.5 µV/V/°C
Weight: 0.15 Kg
Electric Features:
Maximum excitation voltage: 30Volts
Electrical connection according to DIN 43650
Electrical protection according to
DIN 40050: IP65
Stocking temperature: from -55°C to +125°C
ELECTRIC CONNECTIONS
1 = IN +
2 = OUT +
3 = IN -
T = OUT –
We reserve the right to make construction modifications without prior
notice.
|
Type
|
Measuring interval
|
Maximum pressure
|
|
TD 60.1
|
0 > 2 Bar
|
7.5 Bar
|
|
TD 60
|
0 > 5 Bar
|
12 Bar
|
|
TD 61
|
0 > 10 Bar
|
25 Bar
|
|
TD 62
|
0 > 20 Bar
|
50 Bar
|
|
TD 63
|
0 > 50 Bar
|
120 Bar
|
|
TD 64
|
0 > 100 Bar
|
250 Bar
|
|
TD 65
|
0 > 200 Bar
|
500 Bar
|
|
TD 69
|
0 > 400 Bar
|
600 Bar
|
|