Schrupp Industries Inc

System Solutions for Industry

 

Descaling Valves Size Dn 63-250 (2.5”-10”)

Schrupp descaling valves are 2 way cartridge type valves especially designed to withstand the high pressures and levels of contamination found in typical steel mill descaling systems.  Schrupp valves are operating worldwide in continuous duty processes with excellent results.

The Schrupp cartridge design is extremely maintenance friendly.  The poppet, sleeve, and seat are completely manufactured out of stainless steel.  The use of a soft seal in the seat area allows complete repair of the valve without the necessity of any machining procedures. 

This is an overview of the descaling valve program.  For dimensional information and more complete details, please see our “Cartridge Program” catalog.

Please do not hesitate to ask us for additional information. 

 

 

Schrupp Descaling Valves Type 1

These valves are electro-pneumatically piloted and can be used for leak free operation.  The robust construction is designed for long service life and safety even in the harsh environment of typical steel mill descaling systems.  This design can also be used for accumulator safety functions or as a pilot operated check valve when pilot pressure is taken from the B port.

 

 

Pressure                     350 bar (5000 psi)

Flow (Maximum)              30,000l/min(7900 gpm)

Recommended Filtration

Main Valve                    100 micron

Pilot Valve                      50 micron

Pneumatic Pressure     5-10 bar (70 to 145 psi)

Pilot Area Ratio:            2:1

 

Pilot Valve

 

Electro-pneumatic operated pilot valve, size 10 and 25, 3 way 2 pos, soft seated, leak free.

Voltage:  12V, 24V DC 110V, 220V-50/60Hz AC

Pressure:

Pneumatic to10 bar

Hydraulic to 350 bar

 


 

Schrupp Descaling Valves Type 2

These valves are electro-pneumatically piloted, cylinder operated, with individually adjustable opening and closing speed.  This design is particularly effective in descaling systems with higher levels of contamination and does not require a pilot filtration system.  The robust construction is designed for long service life and safety even in the harsh environment of the typical steel mill descaling system.

Pressure                       350 bar(5000psi)

Flow (Maximum)            30,000 l/mi  (7900 gpm)

Recommended Filtration

Main Valve                    100 micron  

Pilot Valve                     50 micron

Pneumatic Pressure       5-10 bar  (70 to 145 psi)

Pilot Area

Ratio:                            2:1

 

Pilot valve

Electro-pneumatic, cylinder operated pilot valve, sizes 16 and 25 2/2 way cartridge design.  Pilot flow to tank when valve is in open position.

Voltage: 12V, 24V DC, 110V, 220V-50/60Hz, AC

Pressure:

Pneumatic to10 bar Hydraulic to 350 bar

 

Schrupp Descaling Valves Type 2

These valves are electro-pneumatically piloted, cylinder operated, with individually adjustable opening and closing speed.  This design is particularly effective in descaling systems with higher levels of contamination and does not require a pilot filtration system.  The robust construction is designed for long service life and safety even in the harsh environment of the typical steel mill descaling system.

Pressure                        350 bar (5000 psi)

Flow (Maximum)            30,000 l/min (7900 gpm)

Recommended Filtration:

Main Valve                    100 micron

Pilot Valve                     100 micron

Direct Solenoid Pilot        25 micron

Pilot Area Ration:            2:1

 

Pilot valve

Electro-pneumatic, cylinder operated pilot valve, sizes 16 and 25 2/2 way cartridge design.  Pilot flow to tank when valve is in open position.

Voltage: 12V, 24V DC, 110V, 220V-50/60Hz, AC

Pressure:

Pneumatic to10 bar Hydraulic to 350 bar

 


Schrupp Descaling Valve Type 3  
These valves are electro-hydraulically pilot operated.  The direct operated solenoid valves control two size DN25 pilot cartridges which control pilot flow into and out of the main cartridge pilot area.  The pilot medium can be water, oil, or filtered operating system medium.  The opening and closing times are independently adjustable.   The robust construction is designed for long service life and safety even in the harsh environment of the typical steel mill descaling system.

Pressure                        350 bar (5000 psi)

Flow (Maximum)            30,000 l/min (7900 gpm)

Recommended Filtration:

Main Valve                    100 micron

Pilot Valve                     100 micron

Direct Solenoid Pilot        25 micron

Pilot Area Ration:            2:1

 

Pilot valve

Electro-hydraulically operated pilot valve, size Dn25. 3/2 Way directional type, Leakage free, with external “x” pilot  port.

Voltage: 12V, 24V DC, 110V, 220V-50/60Hz, AC

Pressure

Hydraulic to 350 bar