Pilot Valves
3/2 Way Pilot Valve Series P1P
| Pilot valves Type 1 are used for control of Schrupp water hydraulic valves, especially in those systems with contaminated media such as descaling systems. These robustly designed valves can also be used as directional control valves. |
|
|
|
Techncal Data: Size ...... 10, 25 mm Hydraulic Pressure 400bar max Pneumatic Pressure 3-10bar Filtration Requirement 50 mic
|
Installation: Horizontal (others possible) Electrical Power Consumption: 8W Voltage Tolerance: 10% Electrical Protection: IP65
|
|
2/2 Way Pilot valve Series P2P/P2R
| Pilot valves Type 2 are used for control of Schrupp water hydraulic valves, especially in those systems with contaminated media such as descaling systems. These rebustly designed valves are frequently used without pilot filtration and can also be used as 2/2 way directional control valves |
|
|
Technical Data: Size 16, 25 mm Hydraulic pressure 350bar max Pneumatic pressure 2-10bar Recommended filtration 50 mic Electrical power consumption 8W Voltage tolerance 10% Electrical protection IP65
|
|
3/2 Way Pilot valve Series P3P/P3Z
| Pilot valves Type 3 are used for the control of Schrupp water hydraulic valves including 2/2, 3/2, and 4/3 way directional control valves, solenoid operated relief valves, and pump unloading valves. These valves are direct operated solenoid, seated 3/2 way design. | Function
Positive T A P (Normally Open) |
|
Technical Data: Size .... 2 mm Hydraulic Pressure 400 bar max Recommended Filtration 10 mic Installation: vertical (others possible) Electrical Power Consumption 20W Voltage Tolerance 10% Electrical Protection IP65
|
Negative P A T (Normally Closed) |